906 resultados para Contrast sensitivity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To explore the effects of glaucoma and aging on low-spatial-frequency contrast sensitivity by using tests designed to assess performance of either the magnocellular (M) or parvocellular (P) visual pathways. METHODS: Contrast sensitivity was measured for spatial frequencies of 0.25 to 2 cyc/deg by using a published steady- and pulsed-pedestal approach. Sixteen patients with glaucoma and 16 approximately age-matched control subjects participated. Patients with glaucoma were tested foveally and at two midperipheral locations: (1) an area of early visual field loss, and (2) an area of normal visual field. Control subjects were assessed in matched locations. An additional group of 12 younger control subjects (aged 20-35 years) were also tested. RESULTS: Older control subjects demonstrated reduced sensitivity relative to the younger group for the steady (presumed M)- and pulsed (presumed P)-pedestal conditions. Sensitivity was reduced foveally and in the midperiphery across the spatial frequency range. In the area of early visual field loss, the glaucoma group demonstrated further sensitivity reduction relative to older control subjects across the spatial frequency range for both the steady- and pulsed-pedestal tasks. Sensitivity was also reduced in the midperipheral location of "normal" visual field for the pulsed condition. CONCLUSIONS: Normal aging results in a reduction of contrast sensitivity for the low-spatial-frequency-sensitive components of both the M and P pathways. Glaucoma results in a further reduction of sensitivity that is not selective for M or P function. The low-spatial-frequency-sensitive channels of both pathways, which are presumably mediated by cells with larger receptive fields, are approximately equivalently impaired in early glaucoma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To determine the age-related change in the peripheral short-wavelength-sensitive (SWS) grating contrast sensitivity function (CSF), cut-off spatial frequency (acuity) and contrast sensitivity for both a detection and resolution task were measured at 8 degrees eccentricity under conditions of SWS-cone isolation for 51 subjects (19-72 years). The acuity for both the detection and resolution task declined with age, the detection acuity being significantly higher than the resolution acuity at all ages (p

Relevância:

100.00% 100.00%

Publicador:

Resumo:

What is the best luminance contrast weighting-function for image quality optimization? Traditionally measured contrast sensitivity functions (CSFs), have been often used as weighting-functions in image quality and difference metrics. Such weightings have been shown to result in increased sharpness and perceived quality of test images. We suggest contextual CSFs (cCSFs) and contextual discrimination functions (cVPFs) should provide bases for further improvement, since these are directly measured from pictorial scenes, modeling threshold and suprathreshold sensitivities within the context of complex masking information. Image quality assessment is understood to require detection and discrimination of masked signals, making contextual sensitivity and discrimination functions directly relevant. In this investigation, test images are weighted with a traditional CSF, cCSF, cVPF and a constant function. Controlled mutations of these functions are also applied as weighting-functions, seeking the optimal spatial frequency band weighting for quality optimization. Image quality, sharpness and naturalness are then assessed in two-alternative forced-choice psychophysical tests. We show that maximal quality for our test images, results from cCSFs and cVPFs, mutated to boost contrast in the higher visible frequencies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Colour and luminance-contrast thresholds were measured in the presence of dynamic Random Luminance-contrast Masking (RLM) in individuals who had had past diagnoses of optic neuritis (ON) some of whom have progressed to a diagnosis of multiple sclerosis (MS). To explore the spatio-temporal selectivity of chromatic and luminance losses in MS/ON, thresholds were measured using three different sizes and modulation rates of the RLM displays: small checks modulating slowly, medium-sized checks with moderate modulation and large checks modulating rapidly. The colour of the chromatic stimuli used were specified in a cone-excitation space to measure relative impairments in red–green and blue–yellow chromatic channels. These observers showed chromatic thresholds along the L/(L + M) axis that were higher than those along the S-cone axis for all display sizes/modulation rates and both red-green and blue-yellow colour thresholds were higher than luminance-contrast thresholds. The principal change in thresholds with spatio-temporal changes in the display was a reduction in thresholds for L/(L + M) and S-cones with increasing check size and modulation rate. However, luminance contrast thresholds did not change with display size/rate. These results are consistent with MS/ON selectively affecting processing in colour pathways rather than in the magnocellular pathway, and that within the colour pathways neurones with opposed L- and M-cone inputs are more damaged than colour-opponent neurons with input from S-cones.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. To compare the reliability, validity, and responsiveness of the Mars Letter Contrast Sensitivity (CS) Test to the Pelli-Robson CS Chart.

METHODS. One eye of 47 normal control subjects, 27 patients with open-angle glaucoma, and 17 with age-related macular degeneration (AMD) was tested twice with the Mars test and twice with the Pelli-Robson test, in random order on separate days. In addition, 17 patients undergoing cataract surgery were tested, once before and once after surgery.

RESULTS. The mean Mars CS was 1.62 log CS (0.06 SD) for normal subjects aged 22 to 77 years, with significantly lower values in patients with glaucoma or AMD (P < 0.001). Mars test-retest 95% limits of agreement (LOA) were ±0.13, ±0.19, and ±0.24 log CS for normal, glaucoma, and AMD, respectively. In comparison, Pelli-Robson test-retest 95% LOA were ±0.18, ±0.19, and ±0.33 log CS. The Spearman correlation between the Mars and Pelli-Robson tests was 0.83 (P < 0.001). However, systematic differences were observed, particularly at the upper-normal end of the range, where Mars CS was lower than Pelli-Robson CS. After cataract surgery, Mars and Pelli-Robson effect size statistics were 0.92 and 0.88, respectively.

CONCLUSIONS. The results indicate the Mars test has test-retest reliability equal to or better than the Pelli-Robson test and comparable responsiveness. The strong correlation between the tests provides evidence the Mars test is valid. However, systematic differences indicate normative values are likely to be different for each test. The Mars Letter CS Test is a useful and practical alternative to the Pelli-Robson CS Chart.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Some people who experience migraine demonstrate reduced visual contrast sensitivity that is measurable between migraines. Contrast sensitivity loss to low spatial frequency gratings has been previously attributed to possible impairment of magnocellular pathway function. This study measured contrast sensitivity using low spatial frequency targets (0.25–4 c/deg) where the adaptation aspects of the stimuli were designed to preferentially assess either magnocellular or parvocellular pathway function (steady and pulsed pedestal technique). Twelve people with migraine with measured visual field abnormalities and 17 controls participated. Subjects were tested foveally and at 10° eccentricity. Foveally, there was no significant difference in group mean contrast sensitivity. At 10°, the migraine group demonstrated reduced contrast sensitivity for both the stimuli designed to assess magnocellular and parvocellular function (P < 0.05). The functional deficits measured in this study infer that abnormalities of the low spatial frequency sensitive channels of both pathways contribute to contrast sensitivity deficits in people with migraine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We measured visual performance in achromatic and chromatic spatial tasks of mercury-exposed subjects and compared the results with norms obtained from healthy individuals of similar age. Data were obtained for a group of 28 mercury-exposed subjects, comprising 20 Amazonian gold miners, 2 inhabitants of Amazonian riverside communities, and 6 laboratory technicians, who asked for medical care. Statistical norms were generated by testing healthy control subjects divided into three age groups. The performance of a substantial proportion of the mercury-exposed subjects was below the norms in all of these tasks. Eleven of 20 subjects (55%) performed below the norms in the achromatic contrast sensitivity task. The mercury-exposed subjects also had lower red-green contrast sensitivity deficits at all tested spatial frequencies (9/11 subjects; 81%). Three gold miners and 1 riverine (4/19 subjects, 21%) performed worse than normal subjects making more mistakes in the color arrangement test. Five of 10 subjects tested (50%), comprising 2 gold miners, 2 technicians, and 1 riverine, performed worse than normal in the color discrimination test, having areas of one or more MacAdam ellipse larger than normal subjects and high color discrimination thresholds at least in one color locus. These data indicate that psychophysical assessment can be used to quantify the degree of visual impairment of mercury-exposed subjects. They also suggest that some spatial tests such as the measurement of red-green chromatic contrast are sufficiently sensitive to detect visual dysfunction caused by mercury toxicity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to compare contrast sensitivity estimated from transient visual evoked potentials (VEPs) elicited by achromatic pattern-reversal and pattern-onset/offset modes. The stimuli were 2-cpd, achromatic horizontal gratings presented either as a 1 Hz pattern reversal or a 300 ms onset/700 ms offset stimulus. Contrast thresholds were estimated by linear regression to amplitudes of VEP components vs. the logarithm of the stimulus contrasts, and these regressions were extrapolated to the zero amplitude level. Contrast sensitivity was defined as the inverse of contrast threshold. For pattern reversal, the relation between the P100 amplitude and log of the stimulus contrast was best described by two separate linear regressions. For the N135 component, a single straight line was sufficient. In the case of pattern onset/offset for both the C1 and C2 components, single straight lines described their amplitude vs. log contrast relations in the medium-to-low contrast range. Some saturation was observed for C2 components. The contrast sensitivity estimated from the low-contrast limb of the P100, from the N135, and from the C2 were all similar but higher than those obtained from the high-contrast limb of the P100 and C1 data, which were also similar to each other. With 2 cpd stimuli, a mechanism possibly driven by the M pathway appeared to contribute to the P100 component at medium-to-low contrasts and to the N135 and C2 components at all contrast levels, whereas another mechanism, possibly driven by the P and M pathways, appeared to contribute to the P100 component at high contrast and C1 component at all contrast levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the present study was to measure contrast sensitivity to equiluminant gratings using steady-state visual evoked cortical potential (ssVECP) and psychophysics. Six healthy volunteers were evaluated with ssVECPs and psychophysics. The visual stimuli were red-green or blue-yellow horizontal sinusoidal gratings, 5° × 5°, 34.3 cd/m2 mean luminance, presented at 6 Hz. Eight spatial frequencies from 0.2 to 8 cpd were used, each presented at 8 contrast levels. Contrast threshold was obtained by extrapolating second harmonic amplitude values to zero. Psychophysical contrast thresholds were measured using stimuli at 6 Hz and static presentation. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. ssVECP and both psychophysical contrast sensitivity functions (CSFs) were low-pass functions for red-green gratings. For electrophysiology, the highest contrast sensitivity values were found at 0.4 cpd (1.95 ± 0.15). ssVECP CSF was similar to dynamic psychophysical CSF, while static CSF had higher values ranging from 0.4 to 6 cpd (P < 0.05, ANOVA). Blue-yellow chromatic functions showed no specific tuning shape; however, at high spatial frequencies the evoked potentials showed higher contrast sensitivity than the psychophysical methods (P < 0.05, ANOVA). Evoked potentials can be used reliably to evaluate chromatic red-green CSFs in agreement with psychophysical thresholds, mainly if the same temporal properties are applied to the stimulus. For blue-yellow CSF, correlation between electrophysiology and psychophysics was poor at high spatial frequency, possibly due to a greater effect of chromatic aberration on this kind of stimulus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The luminance contrast sensitivity function has been investigated using behavioral and electrophysiological methods in many vertebrate species. Some features are conserved across species as a shape of the function, but other features, such as the contrast sensitivity peak value, spatial frequency contrast sensitivity peak, and visual acuity have changed. Here, we review contrast sensitivity across different classes of vertebrates, with an emphasis on the frequency contrast sensitivity peak and visual acuity. We also correlate the data obtained from the literature to test the power of the association between visual acuity and the spatial frequency of the contrast sensitivity function peak.